Optionally treat EOF on stdin just like SIGTERM (#111)
* Optionally treat EOF on stdin just like SIGTERM On Unix, Node.js allows us to gracefully kill a process. On Windows this is more compex. You certainly cannot rely on the default `kill()` function, which calls `TerminateProcess`. There is a bunch of C/C++ extensions that in principle allow you to attempt to gracefully shutdown a Windows process. But, hey, here's a reality check. Node.js controls our stdin. Node.js does IPC easy. Controlling uv_spawn flags and using the right not well maintained C/C++ Node.js extension to kill a process is fragile. So, treat EOF and any other error on stdin as equivalent to SIGTERM. However, systemd. The sane thing to do with systemd is `StandardInput=null`. With such configuration, stdin immediately returns EOF. Then, introduce the `OONI_STDIN_EOF_IMPLIES_SIGTERM` environment variable. When it is `true`, this behaviour is enabled, e.g.: ```bash export OONI_STDIN_EOF_IMPLIES_SIGTERM=true # behaviour enabled ooniprobe run ``` I want the default to be disabled because: 1. in the future we may find a better way to solve this problem and I don't want the _default behaviour_ to change in such case 2. we know we need this knob for ooniprobe-desktop, and we will not fail to provide it, so it won't suprise/damage us 3. a person trying to write a systemd unit for ooniprobe would be very surprised to find out they need to disable this behaviour, if it was enabled by default by this PR Hence, I believe this design is consistent with designing for the future and for trying to minimize surprises. Also, why an environment variable and not a command line flag? Because: 1. we don't want such hypothetical flag to be available where it does not make sense, e.g., for all subcommands but `run` 2. we don't want the ooni/probe-desktop app to write conditional code because it needs to check the command we're using and then decide whether to add such hypothetical flag Also, why not enabling this only on Windows? Because again we don't want the ooni/probe-desktop app to write conditional code. To summarize: we want ooni/probe-desktop app to see the same behaviour everywhere and we want others to be the least surprised. Related to https://github.com/ooni/probe/issues/1005 * Update ooni.go
This commit is contained in:
parent
ac893c9095
commit
040bee0ee6
|
@ -2,9 +2,6 @@ package run
|
|||
|
||||
import (
|
||||
"errors"
|
||||
"os"
|
||||
"os/signal"
|
||||
"syscall"
|
||||
|
||||
"github.com/alecthomas/kingpin"
|
||||
"github.com/apex/log"
|
||||
|
@ -16,22 +13,6 @@ import (
|
|||
"github.com/ooni/probe-cli/nettests"
|
||||
)
|
||||
|
||||
// listenForSignals will listen for SIGINT and SIGTERM. When it receives those
|
||||
// signals it will set isTerminatedAtomicInt to non-zero, which will cleanly
|
||||
// shutdown the test logic.
|
||||
// TODO refactor this to use a cancellable context.Context instead of a bool
|
||||
// flag, probably as part of: https://github.com/ooni/probe-cli/issues/45
|
||||
func listenForSignals(ctx *ooni.Context) {
|
||||
s := make(chan os.Signal, 1)
|
||||
signal.Notify(s, os.Interrupt, syscall.SIGINT, syscall.SIGTERM)
|
||||
|
||||
go func() {
|
||||
<-s
|
||||
log.Info("caught a stop signal, shutting down cleanly")
|
||||
ctx.Terminate()
|
||||
}()
|
||||
}
|
||||
|
||||
func runNettestGroup(tg string, ctx *ooni.Context, network *database.Network) error {
|
||||
group, ok := nettests.NettestGroups[tg]
|
||||
if !ok {
|
||||
|
@ -46,7 +27,8 @@ func runNettestGroup(tg string, ctx *ooni.Context, network *database.Network) er
|
|||
return err
|
||||
}
|
||||
|
||||
listenForSignals(ctx)
|
||||
ctx.ListenForSignals()
|
||||
ctx.MaybeListenForStdinClosed()
|
||||
for i, nt := range group.Nettests {
|
||||
if ctx.IsTerminated() == true {
|
||||
log.Debugf("context is terminated, breaking")
|
||||
|
|
47
ooni.go
47
ooni.go
|
@ -3,7 +3,9 @@ package ooni
|
|||
import (
|
||||
"io/ioutil"
|
||||
"os"
|
||||
"os/signal"
|
||||
"sync/atomic"
|
||||
"syscall"
|
||||
|
||||
"github.com/apex/log"
|
||||
"github.com/ooni/probe-cli/config"
|
||||
|
@ -51,6 +53,51 @@ func (c *Context) Terminate() {
|
|||
atomic.AddInt64(&c.isTerminatedAtomicInt, 1)
|
||||
}
|
||||
|
||||
// ListenForSignals will listen for SIGINT and SIGTERM. When it receives those
|
||||
// signals it will set isTerminatedAtomicInt to non-zero, which will cleanly
|
||||
// shutdown the test logic.
|
||||
//
|
||||
// TODO refactor this to use a cancellable context.Context instead of a bool
|
||||
// flag, probably as part of: https://github.com/ooni/probe-cli/issues/45
|
||||
func (c *Context) ListenForSignals() {
|
||||
s := make(chan os.Signal, 1)
|
||||
signal.Notify(s, os.Interrupt, syscall.SIGINT, syscall.SIGTERM)
|
||||
go func() {
|
||||
<-s
|
||||
log.Info("caught a stop signal, shutting down cleanly")
|
||||
c.Terminate()
|
||||
}()
|
||||
}
|
||||
|
||||
// MaybeListenForStdinClosed will treat any error on stdin just
|
||||
// like SIGTERM if and only if
|
||||
//
|
||||
// os.Getenv("OONI_STDIN_EOF_IMPLIES_SIGTERM") == "true"
|
||||
//
|
||||
// When this feature is enabled, a collateral effect is that we swallow
|
||||
// whatever is passed to us on the standard input.
|
||||
//
|
||||
// See https://github.com/ooni/probe-cli/pull/111 for more info
|
||||
// regarding the design of this functionality.
|
||||
//
|
||||
// TODO refactor this to use a cancellable context.Context instead of a bool
|
||||
// flag, probably as part of: https://github.com/ooni/probe-cli/issues/45
|
||||
func (c *Context) MaybeListenForStdinClosed() {
|
||||
if os.Getenv("OONI_STDIN_EOF_IMPLIES_SIGTERM") != "true" {
|
||||
return
|
||||
}
|
||||
go func() {
|
||||
defer c.Terminate()
|
||||
defer log.Info("stdin closed, shutting down cleanly")
|
||||
b := make([]byte, 1<<10)
|
||||
for {
|
||||
if _, err := os.Stdin.Read(b); err != nil {
|
||||
return
|
||||
}
|
||||
}
|
||||
}()
|
||||
}
|
||||
|
||||
// Init the OONI manager
|
||||
func (c *Context) Init(softwareName, softwareVersion string) error {
|
||||
var err error
|
||||
|
|
Loading…